Project Profile: Large-scale resort designed and consructed

M Resort is a full-service hotel, casino, and spa just south of Las Vegas Boulevard.

09/11/2017


Project name: M Resort
Project type: Design-Build
Engineering firm: Marnell Corrao Associates
Building type: Resort/Hotel/Casino
Location: Henderson, NV
Timeline: June 1, 2007- March 31, 2009

Background

Located just south of the Las Vegas Boulevard, M Resort is a full-service hotel, casino, and spa. In 2007, the M Resort embarked on a large-scale design and construction project to build the one million square foot facility. The facility consisted of a 12-story hotel tower, 390 guest rooms, 90,000 square feet of gaming space, 40,000 square feet of convention facilities, a full-service spa, multiple restaurants, and an 800,000 square foot parking garage.

Southland employed the use of 3D modeling software to ensure constructability of the design. Courtesy: Southland IndustriesApproach

Southland’s scope of work included design-build services for all mechanical, plumbing, and fire protection systems for M Resort’s low-rise building, 12-story hotel tower, and central plant. The timeline for completing the project required careful planning and diligent monitoring of progress during construction. To remain on top of the aggressive project schedule, Southland employed the use of 3D modeling software to coordinate trades and included trade supervision early in the planning process to ensure constructability of the design. Southland fabricated much of the mechanical and plumbing systems within their shop, resulting in safer and more efficient field installation.

To accommodate the different uses of each space and ensure occupancy comfort, the project team installed 430 variable air volume (VAV) terminal units with reheat as the primary air-distribution system. Southland’s design also included a central controls system that allows the building operators to monitor and change settings remotely.

Results

Southland’s approach ensured that the aggressive timeline for the project was met by designing and installing efficient units to meet the complex needs of the owner and facilities staff. Southland’s work on the project was also recognized with a Contracting Business Design/Build Award for New Construction.

This article originally appeared on Southland's website. Southland industries is a CFE content partner. Edited by Hannah Cox, content specialist, CFE Media, hcox@cfemedia.com.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me