Project profile: Energy-efficient K-12 school

The building’s MEP design follows a city-wide effort to reduce consumption of fuel and electrical power and is designed to be 50% more efficient than energy code requirements.

10/02/2014


Project Name: Metropolitan Business Academy

Building exterior. Courtesy: S/L/A/M Architecture.Project Type: New construction

Engineering Firm: OLA Consulting Engineers

Architect: S/L/A/M Collaborative

Building Type: K-12 School

Location:
New Haven, CT

Timeline:
December 2006 - June 2011



Building details

The new 4-story Metropolitan Business Academy is an 86,000 sq ft building that is home to students in grades 9 through 12 in New Haven, CT. The building contains 5 full computer labs, a first floor atrium space and a cafeteria flooded with natural light, video editing room, cone-shaped 105-seat lecture hall with video conferencing, teacher's resource room, and classrooms with LCD projectors.


Sports center. Courtesy: S/L/A/M Architecture.Project details
The building's MEP design follows a city-wide effort to reduce consumption of fuel and electrical power and is designed to be 50% more efficient than energy code requirements. Energy efficient features include:

  • Electrical: Low lighting power density and advanced lighting controls help achieve an almost 66% reduction in energy use intensity.
  • Mechanical: High efficiency chiller plant with thermal storage, high efficiency boiler plant, demand controlled ventilation, and bi-polar ionization air treatment.
  • Fire Protection and Plumbing Services: Sprinkler hydraulic calculations, smoke dampers, and a wet pipe system throughout. Plumbing services included back flow preventor, toilet rooms, kitchen, domestic water heating systems, fuel systems, and roof drainage. 

 

Student commons. Courtesy: S/L/A/M Architecture.Challenge and solution
Since this project is located near the intersection of two interstate highways and a heavily traveled State highway, the air quality for outdoor air intake is very poor. In order to properly treat the ventilation air and provide acceptable indoor air quality a bi-polar ionization air treatment system was installed allowing outdoor air ventilation rates to be reduced and additional energy saved.

Project results
One year of utility data, energy efficiency information, or other data prove the project's success. The design phase energy model calculated an energy use intensity (EUI) of 44.0 kBTU/sq ft for the building. After being constructed and operating for a year, the actual building energy use intensity as indicated by utility meter readings for the year was 45.9 kBTU/sq ft, a difference of only 4.3% of the theoretical model.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me