Project profile: Chillers installation on college campus

A new 7,500 sq ft construction is designed to support Broward College Campus. It includes installing two 750-ton water cooled chillers and space for three more chillers in future.

10/03/2014


 

Project name: Broward College expansion

Project type: New construction

Engineering Firm: SGM Engineering Inc.

Building type:
Educational facilities

Location:
Davie, FL

Timeline: February 2014 - December 2014


Project details
A new 7,500 sq ft construction is designed to support Broward College Campus. It includes installing two 750-ton water cooled chillers and space for three more chillers in future. However, all the provision for additional chillers are made. This plant will be synchronized with other existing plants, to maximize efficiencies and reduce operating and maintenance cost. The entire campus has a chilled water storage tank, which will support campus HVAC needs. The local power company will issue a minimum of $10,000 energy rebate as result of this project.




Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me