Profinet modules added to automation product range

The LioN-M IO Profinet module by Belden has been added to the Lumberg Automation product range. The modules support real time (RT) and isochronous real time (IRT) standards.

07/11/2012


Belden Inc. has added LioN-M I/O Profinet modules to its Lumberg Automation product range. The Profinet I/O modules support both real time (RT) and isochronous real time (IRT) standards. 

In the 0980 ESL 701 (16DI) module, channels are used as inputs, and in the universal version 0980 ESL 700 (16DIO Universal) they are used as either inputs or outputs in any combination up to a total of 16 points. The 0980 ESL 700 has a rated output current of up to 1.6A, with a maximum total current capacity of 9A. The diagnostic concept enables precise fault location for each individual port. Both modules facilitate line topologies and can also be used for existing communications structures such as cable ducts and energy chains without making any changes to their physical layout. The universal module offers flexibility not only at the planning stage, but also when making changes at the commissioning stage or during subsequent upgrades. 

Both network ports are equipped with four-pole M12 connectors with D coding. The eight I/O ports, each of which can be assigned to two digital I/O signals, have five-pole M12 connectors with A coding. The network ports are color-coded to prevent any possible confusion. These Profinet IO modules support DCP and LLDP. DCP protocol is used to assign the unique Profinet device name to the module. By this device name the module is clearly identified in the Profinet network.  

The I/O modules have a robust housing made of PBT (polybutylene terephthalate) and measures 243 x 60 x 23 mm. Both versions meet the requirements for industrial protection class IP67 and are designed for temperatures ranging from 10 C to +60 C. The power supply, which is connected via two five-pole 7/8 in. connectors, has a rated voltage of 24 V and a range of 11 V to 30 V. 

Belden Inc.

www.belden.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
January/February 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me