Professional Engineering Consultants PA: Wichita Dwight D. Eisenhower National Airport

Automation, controls; electrical, power; HVAC, mechanical; lighting; energy, sustainability; plumbing, piping.

08/11/2016


Engineering firm: Professional Engineering Consultants PA

2016 MEP Giants rank: 92

Project: Wichita Dwight D. Eisenhower National Airport

Location: Wichita, Kan.

Building type: Utilities/public works/transportation; airport

Project type: New construction

Engineering services: Automation, controls; electrical, power; HVAC, mechanical; lighting; energy, sustainability; plumbing, piping

Project timeline: September 2012 to June 2015

MEP/FP budget: Confidential

A major upgrade to the new airport was the expanded baggage claim area with three carousels with digital billboards. Courtesy: Gavin PetersChallenges

The last time Wichita celebrated a new airport was 1954, and it was past due for an upgrade. Renovating the existing building proved too expensive. Professional Engineering Consultants provided mechanical, electrical, and civil engineering services for the new terminal and terminal apron relocation to bring a world-class airport terminal to the city known as the "Air Capital of the World." One of the challenges for this project involved keeping the existing terminal and apron operational during construction. To address this, a new terminal was constructed adjacent to the old one. Other challenges included an existing remediation well that had to stay in use throughout construction as well as be rerouted, because the existing discharge line was located under the new terminal unit. The height of the existing air-traffic control tower set the maximum height for the new terminal building, which presented another challenge—a low floor-to-ceiling height in the lower level that housed the mechanical and electrical rooms.

Solutions

Turning the Wichita Mid-Continent Airport into the Dwight D. Eisenhower National Airport required keeping airport operations functioning throughout the transition. During construction of the new terminal, a tunnel was constructed between the two buildings to allow utilities and communications to exist between the buildings. The phases were strategically planned to assure air traffic was not interrupted. The remediation well issue was addressed by piping the well water through the tunnel, then through a series of heat exchangers serving various uses such as air tempering, radiant cooling, snowmelt, and condenser-water supplemental cooling. This solution rerouted the line as needed, with the added benefit of heat recovery. To address the lower ceiling space, tight coordination between mechanical and electrical engineering, low-voltage electrical systems, structural engineering, and baggage handling assured the systems fit in the allotted, shorter space. Close collaboration with vendors during installation proved critical to resolve design differences quickly and keep the terminal's opening schedule on track.

Read more about the project by downloading this PDF.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me