Product Rating Manual for Acoustical Duct Silencers

AMCA International reaffirmed AMCA publication 1011-03, a Certified Ratings Program Product Rating Manual for Acoustical Duct Silencers, and provides a program for certifying a product's sound dynamic insertion loss, airflow generated noise, and pressure drop performance ratings. Products that can be licensed by AMCA to bear the AMCA Certified Ratings Seal are prefabricated acoustical duct sile...

04/01/2010


 

 

 

AMCA International reaffirmed AMCA publication 1011-03, a Certified Ratings Program Product Rating Manual for Acoustical Duct Silencers, and provides a program for certifying a product's sound dynamic insertion loss, airflow generated noise, and pressure drop performance ratings.

 

Products that can be licensed by AMCA to bear the AMCA Certified Ratings Seal are prefabricated acoustical duct silencers. Prefabricated acoustical duct silencers are defined as silencers that are constructed in advance, or manufactured in standard assemblies or sections ready for field installation.

 

The program applies to acoustical duct silencers within the scope of AMCA International for which performance rating catalogs are published and made available to the public. When performance ratings for both licensed and unlicensed products are contained in the same catalog, a clear distinction must be made between licensed and unlicensed products, as required in Section 11 of AMCA International Publication 11, Certified Ratings Program Operating Manual.

 

When licensed products are used as component parts of a larger unit, the AMCA International Certified Ratings Seal shall not be applied to the complete unit. The seal can only be applied to the individually licensed components.

 

 

 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me