Product Exclusive: Panel wiring system saves time, space

Eaton transforms panel wiring, lowering total cost of ownership, improving system reliability for original equipment manufacturers. This is a March 2011 Control Engineering Product Exclusive.

03/21/2011


Diversified industrial manufacturer Eaton Corporation is introducing the Eaton SmartWire-DT panel wiring solution into the United States. SmartWire-DT is designed to reduce panel wiring complexity, improve system reliability, save installation time, and reduce panel space. It replaces the myriad of wires found in the control circuit with one cable, connecting motor control components to customers’ programmable logic controllers (PLCs). It changes the way original equipment manufacturers (OEMs) build control panels.

SmartWire-DT transforms standard motor control components into communication-enabled devices and connects them within the panel as well as in separate distribution panels, or in remote control stations. By connecting control devices using quick connectors, OEMs save time by having less fault prone point-to-point wiring.

Richard Chung, product manager, Eaton, said, “SmartWire-DT is engineered to reduce panel wiring complexity and assembly labor time, speed the startup commissioning processes, and provide extensive run-time diagnostics.” It eliminates the time needed to cut, strip, mark, bundle, and check numerous individual wires. Flat cable connections safeguard the control panel from unauthorized wiring changes, helping to protect the craftsmanship and integrity of the control panel. An eight-conductor, flat cable located in the control cabinet connects motor starters, pushbutton actuators, indicator lights, and other components. The SmartWire-DT gateway connects to standard programmable logic controller (PLC) fieldbuses, including Profibus-DP and CANopen.

Because the product integrates the input/output (I/O) level in the switching devices, no conventional PLC I/O modules are needed; communication-enabled modules attach to standard Eaton motor control components. The PLC in the control cabinet simply consists of a central processing unit (CPU).

Using the flat cable and special connectors reduces typical faults—like loose connections and mis-wired terminations. Each SmartWire-DT enabled device has individual status indicators to reduce commissioning time and troubleshooting in the field. Connected devices are automatically addressed with the push of a button on the gateway, assigning addresses in the order that the devices are connected. The system continuously monitors all networked devices and panel changes. The network functions up to 2,000 ft and can connect up to 99 devices per gateway.

www.eaton.com

Eaton

DID YOU APPLY FOR, TURN IN A CONTROL PANEL DESIGN TUTORIAL VIDEO? www.controleng.com/controlpanelcontest



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me