Product Exclusive: Large, color PLC+HMI touchscreen

Unitronics new Vision1210 is an industrial programmable logic controller integrated with a 12.1-in. color human-machine interface with touchscreen.

06/22/2011


Unitronics' Vision1210 is fully programmable logic controller with a 12.1-in. color touchscreen.Unitronics introduces the newest big-screen member of its PLC+HMI family, the Unitronics Vision1210. Industrial control processes can now enjoy full programmable logic controller (PLC) functionality with a larger-than-ever 12.1-in., 65,000-color touchscreen. Integrating a PLC and HMI gives users an opportunity to operate on a minimum of budget, programming time, and wiring, the company said.

With an IP66 rating, the controller is well suited for the food industry, wherever spray or wipe down applications apply. A wide variety of onboard I/O options can be added by snapping a module onto the back of the PLC. Expandable up to 1,024 I/O, these configurations include digital and analog inputs and outputs, high-speed I/O, PT100/thermocouple capabilities, and weight measurement. They can be mounted locally or remotely, up to 1000 m from the controller. This power-PLC is equipped with a built-in USB programming port, recipe capabilities, Micro SD card memory storage for data logging and backup, complete PLC cloning, and more.

Systems integrators can now rely on one device: The Vision1210 can support 24 auto-tuned PID loops to control temperature, level, and pressure, while the 16-bit SVGA color touchscreen displays data, color trend graphs, and attention-grabbing alarm screens. Display options are almost endless, with more than 1,000 user-designed screens, and up to 500 images per application. Internal memory holds 2 MB of application logic, plus 1 MB for fonts and 32 MB for images.

Communication options include TCP/IP Ethernet, cellular, and industrial protocols, such as Modbus, DF1 slave, J1939, CANopen, and others. In addition, the controller can be “taught” to communicate via almost any device-based protocol. It also is capable of time-based and immediate interrupts, making it a natural for rapid-response applications, such as packaging machines.

Unitronics’ free VisiLogic software provides one user-friendly environment for hardware configuration, modular Ladder application development, and HMI design, including a rich color library of industrial images, the company said. Unitronics also offers free technical support for all products.

Vision1210 reduces overall system costs by minimizing hardware requirements, saving cabinet space, and—above all—exempting the user from setting up panel-PLC communication.

www.unitronics.com Unitronics



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me