Product Exclusive: Dataforth 8B isoLynx SLX300 DAQ system

A new data acquisition system from Dataforth, with application software and isolated signal conditioning modules are said to offer superior reliability and isolation. Dataforth ReDAQ Shape DAQ software allows users to easily create, save, and open graphical user interface projects, as well as to test, process, and analyze acquired data, the company says. This is an October 2010 Control Engineering Product Exclusive.

10/18/2010


Dataforth 8B isoLynx SLX300, a new data acquisition system, builds on the proven reliability and performance of the Dataforth SCM5B isoLynx SLX200 and miniature SensorLex 8B isolated signal conditioning modules to provide a compact, low cost solution for wide ranging rugged industrial applications.

Dataforth ReDAQ Shape, out-of-the-box DAQ software for the SLX300, provides the easiest and most efficient development tool to create, save, and open graphical user interface projects as well as to test, process, and analyze acquired data. The software provides the most effective way to set up and configure SLX300 functions.

The data acquisition system features:

  • Modbus RTU and TCP support;
  • 1500 V rms input-to-output and channel-to-channel Isolation;
  • 240 V rms field-side protection;
  • Wide I/O selection;
  • Mix and match analog and digital I/O;
  • Advanced features including alarms, counters, timers and PWMs; and
  • CE and RoHS compliant, C-UL-US (Class 1, Div 2, Groups A,B,C,D) pending.

Modular design provides the system with flexibility: users can choose from 70 analog and 14 digital I/O modules and configure the system with up to 12 channels of isolated analog input, 4 channels of isolated analog output, and 8 channels of isolated digital I/O.

Ensuring broad functionality, the 8 digital I/O channels can be configured to perform seven advanced special functions: pulse/frequency counter, pulse/frequency counter with de-bounce, waveform measurement, time between events, frequency generator, PWM generator, and one-shot pulse generator. The SLX300 also enables four alarm states – high, high-high, low, and low-low – to be set on the analog input and digital I/O special function channels.

High-speed microcontrollers and high performance data converters enable simultaneous analog and digital I/O at sustained rates of up to 3.0 kS/s, as well as high-speed acquisition to 100 kS/s burst on analog input channels. Use of industry standard Modbus RTU or TCP protocols allows communication with third-party software tools and HMI/SCADA packages. Other SLX300 system features include panel or DIN rail mounting and rack-mounted or bench top 1U enclosure. A free configuration tool ensures easy system setup.

www.dataforth.com/catalog/pdf/8BisoLynx_SLX300_Brochure.pdf

www.dataforth.com

Dataforth

- Also read:

Back to Basics: Sensor tips & techniques

Dataforth compact 6.2 mm signal converters

Dataforth DSCA DIN-rail mount isolated analog signal conditioners



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me