Processor module targets cost sensitive applications

Kontron’s Universal AdvancedMC processor module is designed for a wide variety of MicroTCA and AdvancedTCA applications, including: targeted to cost sensitive, powerful data plane, and control plane applications.

07/11/2011


The Kontron AdvancedMC processor module AM4120 is equipped with the Freescale QorIQ P2020 Dual Core processor with up to 1.2GHz and based on the Power Architecture e500. A dedicated Module Management Controller (MMC), which supports basic IPMI commands, is used for board management, enabling operators to monitor the status of the AdvancedMC module in the system. The Kontron AdvancedMC processor module AM4120 also offers increased longevity due to Freescale’s processor availability until at least 2018, careful component selection and a Micro SDHC card socket that is not impacted by regular flash discontinuation.

For flexible data exchange, the Kontron AM4120 features 4x SERDES lines routed to AMC ports 4 – 7, which are configurable either as PCIe (root complex or end point) or SRIO ports (host or agent), for applications which require close programming to the chip without extensive overhead. This makes the Kontron AdvancedMC processor module AM4120 a flexible solution in various system configurations. Additionally, it provides several different boot options for the OS including from an exchangeable Micro SDHC card to simplify updates, a NOR Flash or the soldered NAND Flash for rugged applications. For further flexibility in inter- and intra system communication, the Kontron AM4120 supports up to 3x GbE channels which are routed to AMC port 0 plus 2x RJ45 interfaces at the front or routed to AMC ports 0 and 1 plus one port at the front. Depending on the requirements of the application, the Kontron AdvancedMC processor module AM4120 can be used in system configurations with or without MCH. For rugged applications, the Kontron AM4120 is available on a project basis for the extended temperature range.

Kontron offers various MicroTCA and AdvancedMC systems for the AdvancedMC processor module. For example, the Kontron OM6060 can be used as an entry level platform for operating the Kontron AM4120 with PCIe and SRIO point to point fabrics in combination with the Kontron AM4901 basic MCH which provides Ethernet connectivity to all AdvancedMC slots. In this system, the Kontron AM4120 can be combined with I/O cards, DSP cards and different processor boards.

The Kontron AdvancedMC AM4120 supports Bootloader U-Boot, IPMI, VxWorks 6.9 and Linux LTIB and will be available in sample quantities beginning in July.

www.kontron.com

Kontron

- Edited by Gust Gianos, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me