Pressure-reducing valve

The 3350 pressure-reducing valve (PRV) by Taco automatically feeds water to the hydronic system whenever the pressure drops below the parameter settings.

02/21/2013


The 3350 pressure-reducing valve (PRV) by Taco automatically feeds water to the hydronic system whenever the pressure drops below the parameter settings. Courtesy: TacoTaco’s 3350 pressure-reducing valve (PRV) is used to automatically feed water to a hydronic system whenever pressure in the system drops below the pressure setting of the valve. The 3350 PRV reduces incoming pressure and automatically maintains system pressure to the valve’s adjustable setpoint. If the system pressure drops below the valve’s setpoint, it will automatically add water to the system. The 3350 also features a fast-fill button with automatic reset. All parts for the cartridge-style pressure-reducing valve are contained in a one-piece cartridge that can be easily removed and serviced without reducing system pressure. The device offers a fast-fill mode that automatically returns to normal mode when set pressure is reached. It also delivers increased flow to speed system fill times. Its unique dial-in pressure setting allows for easy adjustment throughout the 10 to 50 psi range, without the need for an external gauge.

Taco

www.taco-hvac.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me