Precipitator control system

HEI Wet Electronic Precipitator System incorporates a unique discharge electrode technology that can be sized to specific applications.

05/04/2017


HEI Wet Electronic Precipitator System incorporates a unique discharge electrode technology that can be sized to specific applications.Bionomic's HEI Wet Electronic Precipitator System incorporates a discharge electrode technology that can be sized to specific applications, and concentrates a high intensity ionizing corona in strategic areas within the collecting tubes instead of distributing it along the entire length of the tubes' treatment area.
The resultant particle charging fields are two to three times stronger than conventional precipitators and deliver higher particulate charges, higher migration velocities, and a smaller precipitator size for gas capacities from 1,000 through 300,000 acfm. Other key features of the system are the available methods for collection tube cleaning, gas precleaning, and conditioning. Unlike other precipitators that utilize sprays, overflow weirs or packed marble beds. The system also comes with PLC-based voltage and spark controls (to maintain maximum electric field stability), nonfouling insulator locations, and new improved materials of construction that provide more resistance to corrosive gases complete the advanced yet economical system.

Bionomic Industries Inc.

www.bionomicind.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me