Power quality analyzer

438-II is 3-phase power quality analyzer that provides frontline troubleshooting and long-term trending to keep equipment running.

05/09/2016


438-II is three-phase power quality analyzer that provides frontline troubleshooting and long-term trending to keep equipment running. Courtesy: FlukeFluke's 438-II is 3-phase power quality analyzer that provides frontline troubleshooting and long-term trending to keep equipment running. It uses innovative algorithms to analyze 3-phase power quality, torque, efficiency, and speed to determine system performance and detect overloaded conditions, eliminating the need for motor load sensors. The 438-II also provides analysis data for both the electrical and mechanical characteristics of the motor. Using proprietary algorithms, it measures the 3-phase current and voltage waveforms and compares them against rated specifications to calculate motor mechanical performance. The analyzer also provides measurements to determine a motor's efficiency and mechanical power under operating load conditions.

Fluke

www.fluke.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me