Power over EtherCAT junction terminal

The Power over EtherCAT junction terminal requires only a standard EtherCAT/Ethernet cable for the fieldbus signal and the power supply. EtherCAT sensors can now receive power over standard Cat 5 cables.

01/27/2009


Power over EtherCAT junction terminal

The EK1132 Power over EtherCAT junction terminal requires only a standard EtherCAT/Ethernet cable for the fieldbus signal and the power supply. Ultra high speed EtherCAT sensors that deliver low microsecond-level communication can now be more easily installed in high performance industrial applications.

The junction is particularly suitable for sensors such as shaft encoders or length-measuring devices that can now be connected via a single cable for reduced wiring efforts. The sensor supply voltage of 48 V is generated in the junction from the 24 V voltage used as the industry standard. The maximum current input of the terminal devices is 350 mA. The signal and energy transfer takes places on the same wire so four-wire cables can be used. The sensors are connected to Power over EtherCAT via a 4-pin connector such as M12. The maximum possible Ethernet cable length is 100 m. An intelligent power distribution system detects which power consumer belongs to which performance class and distributes the total available power (15.4 W) to the connected devices accordingly.

Beckhoff Automation
www.beckhoffautomation.com





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me