Power control systems

Russelectric on-site power control systems are equipped with dual programmable logic controls (PLCs) for automatic generator set starting and stopping, status and alarm annunciation, synchronizing, and priority load control.

05/14/2013


Russelectric on-site power control systems are equipped with dual programmable logic controls (PLCs) for automatic generator set starting and stopping, status and alarm annunciation, synchronizing, and priority load control. Courtesy: RusselectricAll Russelectric on-site power control systems are equipped with dual programmable logic controls (PLCs) for automatic generator set starting and stopping, status and alarm annunciation, synchronizing, and priority load control. A primary PLC system operation with a backup PLC running the same program as the primary. If the primary PLC fails, the backup PLC assumes operational control. If both PLCs were to fail, a manual control system allows operating personnel to synchronize and parallel the generators onto the bus, as well as to add and shed load. This built-in redundancy is included in all Russelectric on-site power control systems. The instruments and other devices that facilitate manual operation (including generator main bus volt meter, frequency meter, and synchroscope) are mounted on a hinged panel that can be specified to swing either left or right for easy viewing from adjacent control cubicles during manual operation. Russelectric custom designs and builds power control and synchronizing switchgear systems in low- and medium-voltage ratings for single- and multi-unit on-site power generators. 

Russelectric 

www.russelectric.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me