Pocket motion controller

The DMC-30017 motion controller combines a single-axis motion controller and a 6A microstepping drive for operating a two-phase bipolar stepper motor.

04/16/2012


The DMC-30017 motion controller combines a single-axis motion controller and a 6A microstepping drive for operating a two-phase bipolar stepper motor. Courtesy: GalilGalil Motion Control announced a stepper motor drive option for their DMC-30000 Pocket Motion Controller Series. The DMC-30017 combines a single-axis motion controller with a 6A microstepping drive. 

The DMC-30017 contains a microstepping drive for operating a two-phase bipolar stepper motor. The drive produces 256 microsteps per full step or 1024 steps per full cycle which results in 51,200 steps/rev for a standard 200-step motor. The maximum step rate generated by the controller is 3,000,000 microsteps/second. The DMC-30017 drives motors operating at up to 6 Amps at 20 to 80 VDC. There are four software-selectable current settings: 0.75A, 1.5A, 3 A, and 6A.

Designed for compact size, the dimensions of the DMC-30017 controller/drive package are 3.9 in.” x 5.0 in.” x 1.5 in.” and no external heat sink is required. 

Other features of DMC-30000 controllers include PID compensation with velocity and acceleration feedforward, non-volatile memory for user programs, multitasking for simultaneously running up to four programs, and I/O processing for synchronizing motion with external events. Modes of motion include point-to-point positioning, position tracking, jogging, contouring, electronic gearing, ECAM, and PVT.

The DMC-30000 provides optically isolated inputs and outputs as a standard feature. I/O include forward and reverse limit inputs, homing input, 8 uncommitted digital inputs, 4 uncommitted digital outputs, 2 uncommitted analog inputs and 1 uncommitted analog output. Two daisy-chainable Ethernet ports are included and an external Ethernet hub is not required. A 115 kb RS232 port is also provided. 

In addition to the DMC-30012 controller/servo drive and DMC-30017 controller/stepper drive packages, the DMC-30000 Series is also available as a controller-only model which can be connected to a stepper or servo motor amplifier of any power range.

Galil Motion Control

www.galilmc.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me