Pneumatic space-saving VUVG valve

Festo’s VUVG pneumatic valves feature a wide valve, thanks to patented cartridge sealing principle.

03/25/2011


TFesto VUVG Valvehe VUVG valves from Festo are reportedly suitable for use in automation applications where cost-effective, small-scale, technologically universal solutions with high flow rates are required, as is the case in the electronics, solar, textile and packaging industries, and in special machine construction. The compact dimensions and low weight of the aluminium housing also make the valves ideal for use in the front-end area, e.g. mounted directly on a robot arm.

More performance, less space

The new valve range sets new standards in terms of the “footprint” compared to valves currently on the market. The “footprint” value describes the size-to-performance ratio. In 90 percent of all applications, a smaller size valve compared to existing valves can often be used according to Festo. VUVG valves of the same size achieve greater dynamics and up to 100 percent more flow for faster cycle times.

Two valves in one

Another cost-reducing factor is the integration of 2 x 3/2-way valves in one valve housing. One VUVG valve is purportedly sufficient for operating two single-acting cylinders. This reduces the required installation space by half.

Patented cartridge sealing principle

The high power density of the VUVG valve is the result of the patented cartridge sealing principle from Festo. Its seal profile allegedly enables vacuum operation, very high flow rates and long life. The cartridge principle enables neatly separated two-pressure operation. With the VUVG, there is reportedly no overlapping between the air ducts.

Easy installation and mounting

A variable electrical connection concept reduces the complexity of ordering and warehousing for all users who require a valve with variable electrics. The patented electronics box can be replaced with just one click. The valve housing remains the same, only the connection option is changed. An astonishing range of variants can be fitted, regardless of the connection options; whether M8 or stranded wire, everything is compatible. And lastly, ordering is simplicity itself thanks to the clearly structured order code.

www.festo.com

Festo

- Edited by Gust Gianos, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me