Plumbing FINALISTS

06/28/2005



Sierra Waterless Urinal by Waterless
No-flush waterless urinals are being given serious consideration by specifiers these days, especially with the continuing growth and popularity of the sustainable design movement. What distinguishes this new model is a full ceramic-glazed interior 2-in. drain line. Neither O-rings nor housings are needed to accept trap cartridges. This newest model takes a standard vertical trap, and the 2-in. waste outlet installs to a 2-in. drain line via standard flanged connection. The units require neither mechanical parts nor water for flushing, with a possible savings of 45,000 gals. of water per year.
The manufacturer suggests that not only does the absence of water make them more hygienic than conventional units, but also, waterless urinals are cheaper to operate. They claim that the waterless units offer a payback period of only three years. www.waterless.com



Equinox Rooftop Water Heater by A.O. Smith
Rooftop tank-type water heater for commercial facilities is claimed by the manufacturer to be an industry first. Designed for installation on a rooftop or other outdoor location, the model was conceived to fulfill the needs of restaurants or similar commercial facilities where interior space is at a premium. The water heater features an 80-gal. storage tank and 120,000 BTU input. Its weight—1,300 lbs.—is said to be comparable to packaged rooftop HVAC units.
A strong plus for this product is that it draws combustion make-up air from the outdoors, eliminating the performance problems for indoor units that are caused by negative air pressure inside buildings. Other key features include: a heavily insulated metal cabinet to house the storage unit; an optional freeze-protection kit that drains the tank in the event of power outages in sub-freezing weather; and full electronic controls for set-point adjustment and system status indications.

www.aosmithwaterheaters.com


CRV Flex Pump Connectors by Metraflex
Pump connectors incorporate a technology developed under a grant from NASA to study and improve turbulence caused by 90-degree elbows in rocket engine test tunnels. Pumps require conditioned non-turbulent flow to operate according to their performance curves. Turbulent flow also results in cavitation and a shorter pump life. The technology from the NASA study was applied by the manufacturer to the HVAC market by incorporating it into its pump connectors. The unit consists of a specially designed set of stationary vanes placed upstream from an elbow as an integral part of the pump connector. The vane imparts a gyroscopic motion to fluid moving through the system, causing it to pass through the elbow uniformly and exit with a flat velocity profile.
The remedies to fluid turbulence used to be a suction diffuser or a long section of straight pipe. The manufacturer of this new product claims that installing vanes in the pump connector reduces installation costs and maintenance when compared to suction diffusers. www.metraflex.com





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me