PLC with built-in HMI operator panel

The Vision1040 from Unitronics is a PLC with a built-in HMI Operator Panel with nine programmable function keys.

12/17/2010


The Vision1040 is a PLC with a built-in HMI Operator Panel comprising a 10.4-in color touch-screen and nine programmable function keys. On-board I/Os can be added by snapping a module onto the back of the PLC; Snap-in I/O Modules come in several configurations. I/O Expansion modules enable integrating up to 1024 I/Os per Vision PLC.

The Vision1040 offers a rich range of embedded features such as multiple auto-tuned PID loops, and internal 120K database for datalogging and recipe programming. Communication options include TCP/IP Ethernet, GSM/SMS, MODBUS and CANopen networking plus remote access for data acquisition and program download. In addition this is reportedly the first Vision controller to comprise a USB programming port.

2MB Ladder code application memory (plus 80MB for images and 1MB for fonts) enable the Vision1040 to run complex control and automation tasks. The 16-bit 65,000-color touch-screen HMI enables the display of color-coded operator instructions and red, attention-grabbing alarm screens. It can also display graphs according to historical values—to reflect trends of recorded data. Display options are almost endless with more than 1000 user-designed screens, and up to 500 images per application.

www.unitronics.com

Unitronics

- Edited by Amanda McLeman, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me