Pipe adapter

Aquatherm's polypropylene-random (PP-R) piping systems now feature a PEX compression adapter made of PP-R and lead-free brass and features a male-end design that allows installers to fuse directly into fusion outlets for faster installation.

06/11/2014


Aquatherm's polypropylene-random (PP-R) piping systems now feature a PEX compression adapter made of PP-R and lead-free brass and features a male-end design that allows installers to fuse directly into fusion outlets for faster installation. Courtesy: AquAquatherm's polypropylene-random (PP-R) piping systems now feature a PEX compression adapter made of PP-R and lead-free brass. This adapter allows installers to easily transition between Aquatherm and PEX in potable water and radiant systems. Aquatherm's PEX adapter is manufactured to ASTM F1960. A male-end design allows installers to fuse directly into fusion outlets, making it quicker and easier to install. The PEX adapter is available in ½-, ¾-, and 1-in. diameters. The compression adapter has a street connection that can be welded directly into an Aquatherm fitting, providing greater ease of use. It uses an expander ring and clamp connection. The PP-R portion of the adapter is made from the same material as Aquatherm Green Pipe and is attached to the zero-lead brass portion.

Aquatherm

www.aquatherm.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me