Photoelectric detector

System Sensor's 2251BR Remote Test Capable photoelectric detector.

04/30/2012


System Sensor’s 2251BR Remote Test Capable photoelectric detector adds simplified remote testing capability to the updated DNR and watertight NEMA DNRW InnovairFlex intelligent duct smoke detector housing. This new detector is especially designed for use in applications requiring a remote test. The “remote test capable” text printed on the detector cover can identify the new 2251BR detector. The detector enables updated DNR (W) duct smoke detectors to be tested remotely when used in conjunction with RTS151 or RTS151KEY remote test stations. This eliminates the need for the DCOIL or external 24 V power to duct smoke installations, thereby reducing the additional first cost and installation labor associated with the DCOIL and pulling external power. The InnovairFlex duct smoke detector can accommodate multiple installation footprints to overcome mounting constraints. It offers superb false alarm immunity, a broad temperature range of –4 to 158 F, easily visible status indicators, and a readily accessible test feature. 

System Sensor 

www.systemsensor.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me