Permanent magnet DC motors from AutomationDirect

IronHorse permanent magnet DC 56C frame motor line includes totally enclosed non-vented and totally enclosed fan-cooled models.

03/11/2010


AutomationDirect IronHorse permanent magnet DC motorsAutomationDirect's new IronHorse permanent magnet DC 56C frame motor line features totally enclosed non-vented (TENV) and totally enclosed fan-cooled (TEFC) models. Motors are constructed of a rolled steel frame with cast aluminum end bell, and are available in sizes ranging from .33 to 2 hp. IronHorse DC motors are useful for applications such as conveyors, turntables, and whenever adjustable speed, constant torque, dynamic braking and reversing capabilities are needed.


IronHorse DC motors have a base 1,800 rpm, and are designed for use on unfiltered SCR (Thyristor) type 115 or 230V rectified ac inputs, when used with an appropriate SCR drive. They may also be used with pulse width modulated (PWM) type DC adjustable speed drives.

Other features include linear speed/torque characteristics over the entire speed range, high starting torques for heavy load applications, reversible rotation, and dynamic braking capability for faster stops. Large brushes provide for longer brush life. All IronHorse DC motors are shipped with a set of brushes in the motor, with an extra set of brushes included in the box. They can be mounted to AutomationDirect's Stable motor slide bases, available in sizes from NEMA 56C to NEMA 449T.

- Edited by Renee Robbins, senior editor
Control Engineering News Desk
More Motors and Drives news from Control Engineering

 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me