Pendent sprinklers for warehouse and storage applications

Model ESFR-25 is an early suppression fast response (ESFR) pendent sprinkler with a K-factor of 25.2 for warehouse and other storage applications.

09/22/2016


Model ESFR-25 is an early suppression fast response (ESFR) pendent sprinkler with a K-factor of 25.2 for warehouse and other storage applications. Courtesy: TycoTyco's Model ESFR-25 is an early suppression fast response (ESFR) pendent sprinkler with a K-factor of 25.2 for warehouse and other storage applications. The sprinkler is UL listed and FM approved and provides a 48-ft ceiling height protection with a minimum 5-ft aisle width. The Model ESFR-25 pendent sprinkler is listed and approved for a range of storage arrangements and commodity classing, including common storage materials, encapsulated and non-encapsulated class I-IV commodities, and expanded and unexpanded plastics. The sprinkler is available with either NPT or ISO threads and with ordinary and intermediate temperature ratings of 165° and 212°F, respectively.

Tyco

www.tyco-fire.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Developing lighting solutions; Designing lighting systems; Integrating fire alarm and HVAC systems
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
Knowing when and how to use parallel generators
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me