Pedestrian walkway gets lighting upgrade

A pedestrian area uses primarily LEDs to light the way between two Chicago buildings.

07/15/2014


 

 

Figure 1: This rendering shows River North Point, a 22,000-sq-ft renovation of a lobby that connects two buildings and a hotel in the heart of Chicago. Courtesy: Perkins+WillThis 22,000-sq-ft lobby renovation in the heart of Chicago connects two buildings and a hotel; about 60,000 pedestrians walk through its doors each day. Programmatic requirements included creating a clean, contemporary aesthetic that enhances pedestrians’ wayfinding. Energy and maintenance reduction as well as long-term flexibility were equally essential. Rich, mahogany-toned wood and live bamboo planters balance the broad spans of warm white stone. A wood screen wall provides a visual separation and subtle wayfinding between the hotel and office lobbies.

The lighting design uses only LED lamp sources, with the exception of linear high performance T8 (HPT8) fluorescent wall washers and ceramic metal halide (CMH) adjustable heads for plant lighting. Square LED downlights with varying lumen output provide cohesion and exemplify the clean aesthetic of the space. After a mockup, 3000 K color temperature was selected to amplify the perception of warmth and comfort. The bamboo, however, required 4000 K to maximize growth, and the design team chose to use both color temperatures. This differential also allows the planters to pop. LED multi-head luminaires demarcate seating areas, while LED linear grazing and cove luminaires enhance the wood screen wall and heighten columns.

At the coffee kiosk, lower-lumen square downlights and LED edge-lit signage create a composition of elements. Continuing this theme, LED decorative-lensed downlights and mini LED cove lights are used in conjunction with wood paneling to wrap the escalators.

The lighting power density is less than 0.75 W/sq ft and beats IECC 2012 by more than 30%.

This project used a DALI-based intelligent control system, which was augmented with daylight and occupancy sensors. By providing an advanced lighting system, the project will not only save significant energy, but will minimize maintenance and increase flexibility and long-term functionality. The addressable nature of the selected control system enables the creation of various lighting scenes, which allows this multifunctional space to be used in several ways and enables the building owner to reprogram as needs change. During commissioning, this flexibility was used at several stages, modifying scenes and adjusting the light levels. In the long run, this system will serve to reduce energy while adding wayfinding, flexibility, and functionality.  

 

 


Shanna Olson is Senior Lighting Designer for KJWW Engineering Consultants. She is NCQLP certified and experienced in creating lighting designs for municipal, health care, educational, commercial, and residential clients. 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me