Patent for CNC adaptive control system

Fanuc Factory Automation America (Fanuc FA America) received a patent for developing on-demand integrated adaptive control for their CNC control system.

06/05/2012


Fanuc Factory Automation America iAdapt S adaptive controls into the CNC system for increased machine tool productivity. It improves material removal and minimizes cycle time by automatically optimizing the cutting feedrate based on the actual spindle load. Courtesy: Fanuc FA AmericaFanuc Factory Automation America ( Fanuc  FA America) and Jerry Scherer, engineer with  Fanuc  FA America, have been awarded a patent for the development of their CNC Adaptive Control System for on-demand integrated adaptive control of machining operations. This system was developed to increase machine tool productivity with  Fanuc  FA America's iAdaptS adaptive control solution.

Fanuc FA America's patented CNC Adaptive Control System measures the present value of the spindle load and then compares this value to a present value of a target spindle load. The adaptive controller is configured to control the feed rate of the machine tool relative to the workpiece to maintain the present value of the spindle load approximately equal to the present value of the target spindle load using one or more calculations of the first feed rate value, the first feed rate dither adjustment value and the second feed rate dither adjustment value.

This CNC adaptive control system is the base technology in  Fanuc  FA America's iAdaptS solution that improves material removal and minimizes cycle time by automatically optimizing the cutting feedrate based on the actual spindle load. Additionally, integration of the iAdaptS software solution within the CNC now eliminates the need for mounting hardware, simplifying installation while improving the capabilities of the original iAdapt product. The original iAdapt product introduced the concept of roughing cycle productivity to CNC customers. The "On Demand" control feature simplified the use of the adaptive control by making it easy to setup and operate. iAdaptS extends tool life by keeping roughing tools fully loaded, putting the heat into the chips rather than the part. As a result, there are fewer minor stoppages which further increases productivity and reduces labor costs.

Fanuc Factory Automation America

www.fanucfa.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

Also see controleng.com/machinecontrol



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me