Panelboard awarded patent for breaker coordination, touchsafe capabilities

ABB received a patent for its ProLine Panelboard, noted for having complete breaker coordination and touchsafe capabilities.

10/07/2011


ABB's Low Voltage Products division has been awarded a United States patent for the advanced current limiting, selective coordination and safety technology of its ProLine Panelboard product. The patent recognizes ProLine Panelboard as the only product of its kind with complete breaker coordination and touchsafe capabilities. ProLine Panelboard is suited for industrial and commercial applications where power reliability and safety of high integrity is required such as critical power, data centers, banking, insurance and medical.

ProLine Panelboard has selective coordination. Selective coordination increases uptime by limiting power outages to the branch of an electrical system where a problem occurs, without knocking out other areas of the system. When a fault occurs the closest overcurrent protective device opens, ensuring that any faults do not cascade upstream. In this way the advanced breaker coordination technology isolates electrical problems, stops nuisance tripping and avoids system-wide blackouts.

ProLine Panelboard isolates the operator during installation and maintenance, eliminating human exposure to any live components. The bus bar is covered and the interior is encased in resin for additional safety. Breaker connections are made in "wells" that prevent any contact with live parts, while containing any arcs that may occur. Traditional US panelboards feature an open architecture with the bus bar structure and breaker hardware void of any insulating material, exposing operators to “live” parts when servicing and installing. Such systems require the operator to manually secure the breaker with a screw directly on the open chassis bus bar. ABB's system features a breaker screw that mechanically secures the breaker with a connection not connected to the bus bar.

www.abb.com

The ABB Group

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me