Panel mount controller for larger robots

The ABB Robotics IRC5 panel-mounted controller's (PMC) functional has been extended for robot model from IRB 2400 to the IRB 7600.

12/30/2011


The IRC5 panel-mounted controller's (PMC) functional has been extended for robot model from IRB 2400 to the IRB 7600. Courtesy: ABB RoboticsABB Robotics has extended the functionality of its IRC5 panel-mounted controller (PMC) to all ABB robots, including its largest robot models. Previously the PMC was only available for models up to the IRB 1600. Featuring a new, large panel mount drive module, PMC “Large” will bring smaller footprint functionality and simplified internal cabling benefits to robot models from the IRB 2400 up to the IRB 7600.

The PMC variant will also make integrating large robots significantly easier by allowing machine builders and system integrators the flexibility to create custom enclosures to best protect the electronics by the means appropriate for specific harsh environments. This will benefit numerous installation types, including food applications that require rigorous washdown capabilities, foundry applications where the moist, dusty atmosphere requires a sealed cooling system, and other environments where the controller may be faced with ignition risks, extreme temperatures or excessive vibration. With panel mounting, the controller can be sealed off from these factors with the best possible enclosure.

The PMC Large offers the full capability of the standard IRC5 controller, just without the full cabinet armor. This facilitates flexible mounting while still delivering the proprietary ABB motion control advantages of QuickMove to assure the shortest possible cycle time, and TrueMove for precise path accuracy and repeatability.

The PMC Large consists of a large drive module and the standard IRC5 control module that can be separately mounted in a variety of configurations, such as on top of each other, side-by-side, or back-to-back. Each module is made up of two layers, the first of which may be folded down for easy access to the second. Up to four drive modules may be connected to the same control module for multiple robot control (MultiMove) or control of additional axes.

The PMC Large is EMC certified, eliminating disturbances to surrounding equipment and allowing for EMC certification of the final enclosed solution.

ABB Robotics

www.abb.com/robotics

- Edited by Chris Vavra, Control Engineering, www.controleng.com

controleng.com/machinecontrol



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me