P2S Inc.: Aquarium of the Pacific, Pacific Visions Expansion

Automation, controls; electrical, power; energy, sustainability; HVAC, mechanical; lighting; plumbing, piping; aquarium; and building addition

08/09/2018


The expansion will feature new animal habitats and 4D theater. Source EHHD Architecture
Engineering firm:
P2S Inc.

2018 MEP Giants rank: 47

Project: Aquarium of the Pacific, Pacific Visions Expansion

Location: Long Beach, CA, United States

Building type: Sports/entertainment/convention center facility

Project type: Addition to existing building

Engineering services: Automation, controls; electrical, power; energy, sustainability; HVAC, mechanical; lighting; and plumbing, piping

Project timeline: May 2013 to June 2017

MEP/FP budget: $363,000

Challenges

The $53 million Pacific Visions expansion is a 29,000-sq-ft, 2-story structure that will feature a state-of-the-art theater. The structure is designed to resemble the shape of a blue whale and has 800 iridescent blue glass panels that take on different hues as the sun and clouds travel through the sky each day. The exhibition consists of a dynamic, 300-person capacity, 4-D theater experience with a high-definition projection system and 130-ft-long curved digital wall projection. The expansion also has 6,000 sq ft of new space for other exhibitions, space for new animal habitats, an art gallery, and 1,700 sq ft of additional retail space.

EHHD designed the Pacific Visions Expansion in Long Beach, CA. Source EHHD Architecture Pacific Visions is set for completion in late 2018. Source P2S Inc.Advanced Engineering Consultants: OSU Kunz-Brundige Franklin County Extension Building

Solutions

As the MEPT and Security design partner, the P2S team was tasked with designing the mechanical, electrical, plumbing, telecom, and security of the aquarium expansion. P2S worked with the project's architect, EHDD, to implement sustainable energy saving solutions that would keep building energy usage below base levels. The aquarium's ownership is deeply attuned to issues of conservation, sustainability and the environment and so they requested that the expansion be designed in an energy efficient manner consistent with their values. This project will seek a Green Globes rating, which is an alternative to LEED certification. P2S also assisted in preparing documentation for the Southern California Edison Savings by Design program, an incentives initiative for efficiently designed buildings.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me