Over the air programming with 802.15.4, ZigBee

New OTA technology from Libelium allows a network to be re-programmed in a couple of minutes by using multihop routing.

06/20/2011


Libelium, a technology company specializing in wireless sensor networks, has announced the launch of Libelium OTA, a solution that lays the foundation for over the air programming (OTAP) for wireless sensor networks and the Internet of Things. This brings OTA capabilities for the first time to unlicensed frequency bands (2.4 GHz, 868 MHz, 900 MHz) and to low power communication using protocols such as 802.15.4 and ZigBee.

Over the last decade wireless programming or over the air provisioning (OTA) has been widely used by the mobile phone industry. This capability has allowed software updates to be delivered to mobile phone users and to enable the deployment of new services as they become available. So far, such capabilities have not been available to wireless sensor networks or to the Internet of Things. Such networks, usually consisting of hundreds or thousands of nodes (“motes”), would benefit from an OTA capability.

David Gascón, Libelium’s CTO, said “Motes are often located in places that are either remote or difficult to access. Libelium OTA will enable firmware upgrades to be made over a wireless network without the need of physical access.” He added, “The new OTAP feature, together with battery recharging via a solar panel, will keep the maintenance costs of wireless sensor networks to a minimum allowing the deployment of networks with thousands of nodes.”

Firmware upgrades can be made within minutes and it is possible to choose between updating single nodes (unicast), multiple nodes (multicast) or an entire network (broadcast). OTA can also be used for the recovery of stuck nodes. Furthermore it is possible to find nodes in a particular area by broadcasting a discovery query.

Libelium OTA can work with both direct-access and multihop-access. In the case of 802.15.4 networks, the nodes to be upgraded can be accessed directly by the gateway. With ZigBee, it is usual that a series of nodes must forward packets sent by the gateway to the chosen destination. When performing OTA with direct access the frequency channel used in the 2.4GHz band is changed so no interferences are caused to the rest of the nodes.

The Libelium OTA provides two levels of security: firstly the data transmitted is encrypted using the AES-128 algorithm; secondly a pass key must be authenticated in each node before the OTA process starts.

For wireless sensor networks implemented with Waspmote, programs sent are stored in a 2GB SD card enabling thousands of software versions to be stored and managed on a single mote. The management OTA application runs in Windows, MacOS and Linux and it is freely available for clients of the Waspmote platform.

Libelium is launching a special training course at their headquarters in Zaragoza, Spain, in June for those interested in learning the OTA capabilities quickly.

The first public demonstration of Libelium OTA was June 6-8, 2011, booth #500 at the Sensors Expo & Conference in Rosemont, IL.

www.libelium.com/ota

Libelium Comunicaciones Distribuidas S.L.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me