Of K-factor, Ground Faults and Simplicity

Specifiers often feel compelled to simplify very complex issues for the benefit of their clients and compatriots in other professions. As they often find, however, oversimplification can be a dangerous thing. And when the issue at hand is system safety, the last thing that engineers want is imprecision.Take electrical systems, for instance.

03/01/2001


Specifiers often feel compelled to simplify very complex issues for the benefit of their clients and compatriots in other professions. As they often find, however, oversimplification can be a dangerous thing. And when the issue at hand is system safety, the last thing that engineers want is imprecision.

Take electrical systems, for instance. These are extraordinarily complex but often beg for simple answers to appease nontechnical and bean-counting types. To be on the safe side, however, long answers may be better.

One example is K-factor, a description of the heating losses a transformer can tolerate when supplying a given nonlinear load. Underwriters' Laboratories (UL) derives K-factor from a well-known standard (ANSI/IEEE C57.110) and tests transformers for coil heating and for proper sizing of the neutral conductor to handle damaging harmonic triplens.

System designers often counsel their clients that any transformers they buy should have K-factors noted on their nameplates. Yet, as any engineer will attest, the UL listing is not a guarantee that harmonics in a facility's electrical system will not ravage transformers and cause danger to occupants and operators. First of all, severe harmonic distortion can cause core heating and mechanical stresses not covered in the UL tests. Part of the design engineer's task is to address system harmonics ; a transformer with a high K-factor by no means absolves the designer of that critical task.

Another area of concern is that transformers with UL-tested K-factor ratings can have high impedance , which may even be a source of harmonic distortion. Core saturation can cause disastrous levels of distortion.

Good engineers make it a practice to explain such complexities to their clients: That transformers may have a distorted output regardless of K-factor, and that electrical system design trumps all in assuring safe facility operation.

Grounded, to a fault

Another area of concern recently has been arcing faults , which also present a safety concern to the operator-and a major design problem for the electrical engineer. Arcing-fault ground currents, for example, are often caused by equipment problems, such as insulation failure and loose component connections. But to associate the phenomenon with cheap or poorly assembled equipment has been a dodge; all consulting engineers and most experienced operators know that poor construction management, equipment mishandling and lack of system maintenance can cause arcing faults.

Preventing arcing faults starts in system design, with the specification of isolated equipment , draw-out features and proper settings for protective devices . When construction is done, the electrical contractor must assure that the system is properly cleaned and ready to be energized.

Consulting and staff engineers must effectively communicate the dangers of arcing faults to clients and operators to instill a sense of responsibility that starts in the design phase and is carried through to routine maintenance.





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me