NZEB examples to inspire

These three facilities are current examples of net-zero energy buildings (NZEB).

07/26/2013


Figure 5: The NREL Research Support Facility in Golden, Colo., has an EUI of 35 kBtu/sq ft/yr, which includes a high-performance data center. Courtesy: NRELBullitt Center, Seattle. Billed as “The Greenest Commercial Building in the World,” the grand opening of this six-story 50,000-sq-ft NZEB was held on Earth Day, April 22, 2013. The building is designed to have an energy use intensity (EUI) of 16 kBtu/sq ft/yr with all energy generation needs supplied by the rooftop solar array.

Melink Headquarters, Milford, Ohio. Designed as net-zero energy capable building and constructed in 2006, renewable energy systems were incrementally added until this 20,000-sq-ft building achieved net-zero energy status in 2011 with an EUI of 18.8 kBtu/sq ft/yr.

NREL Research Support Facility, Golden, Colo. This 360,000-sq-ft net-zero energy office building showcases numerous high-performance design features, many of which are a direct result of NREL research efforts. The building has an EUI of 35 kBtu/sq ft/yr, which includes a high-performance data center. 


Scotte Elliott is an electrical engineer and energy specialist at Metro CD Engineering in Powell, Ohio. He is a Certified Energy Manager, a NABCEP Certified PV Installation Professional, and past division chair of the American Solar Energy Society.

Learn more about net-zero energy design and how to save energy on data centers below. 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me