NYC landmark open with integrated engineering systems

Buro Happold provided structural engineering, MEP engineering, lighting design, and fabrication modeling for the New Amsterdam Plein and Pavilion that commemorates New York City's Dutch founders.

05/13/2011


Buro Happold has welcomed the New Amsterdam Plein and Pavilion, a public structure that celebrates New York City’s Dutch heritage, which formally opened to the public on Thursday, May 12th, 2011. Located in Peter Minuit Plaza next to Manhattan’s Battery Park, the landmark was made possible through a grant from the Netherlands government to celebrate the 400th anniversary of the founding of New Amsterdam. The structure was unveiled in 2009. Its visitor’s information center and a café open to the public for the first time on Thursday.

Buro Happold collaborated with Handel Architects (Architect of Record) and UNStudio (Design Architect/Executive Architect) to design the windmill-shaped structure. Its standout features include:

  • The structure is made of durable, low-maintenance steel and plywood that is covered with a flexible wood fiber surface and coated with Polyurea, a material that is used in the production of spandex, to create a smooth and seamless surface;
  • The fully-integrated structural, MEP systems, and lighting fixtures are concealed in the structure’s shell;
  • The interior is naturally ventilated through shading fins that allow hot air to escape, but guard against rain, and reduce the need for air conditioning and heating;
  • The structural components were designed and produced using a file-to-factory process where computer-controlled machines use digital files to cut and assemble the structural components;
  • An interactive touch screen projection imaging system balances a double-layer dynamic LED lighting system, which allows the glass exterior walls to change colors and glow at night.

- Edited by Amanda McLeman, Consulting-Specifying Engineer, www.csemag.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me