NSF announces certification program for geothermal piping

NSF International, Ann Arbor, Mich., introduced a geothermal listing for piping products that will produce cost-effective and environmentally friendly methods to heat and cool buildings.

08/09/2007


NSF International, Ann Arbor, Mich., introduced a geothermal listing for piping products that will produce cost-effective and environmentally friendly methods to heat and cool buildings.

The U.S. Environmental Protection Agency says that geothermal systems average 40% greater efficiency than air-source heat pump, 48% better than natural gas furnaces and 75% better than oil furnaces.

NSF’s geothermal listing service tests and certifies Polyethylene and Polypropylene piping system products that meet the following requirements:

  • Final performance of the product , which includes testing to ASTM D3035 or AWWA C901 requirements for short-term burst, pressure testing and environmental stress crack resistance

  • Physical properties of the material used in production %%MDASSML%% this testing includes density, flexural modulus, tensile strength, and a PENT of at least 192 hours as required by the Plastics Pipe Institute (PPI) Part Q

  • Long-term hydrostatic stress test %%MDASSML%% includes evaluation of materials to the requirements of the PPI’s Technical Report 3 (PPI TR-3) as well as testing to European and Asian temperature and pressure requirements

  • Health effects testing to ensure compliance with Section 4 of NSF/ANSI Standard 61: Drinking Water System Components -- Health Effects if products are to be used in potable water applications





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me