North Shore Community College Zero Net Energy Building

New construction: North Shore Community College Zero Net Energy Building; RDK Engineers

08/09/2012


NSCC new LEED allied health building, Danvers, Mass. (exterior) (Click to enlarge)Project name: North Shore Community College Zero Net Energy Building

Location: Danvers, Mass.

Firm name: RDK Engineers

Project type, building type: New construction, school (college, university)

Project duration: 1.5 years

Project completion date: Oct. 28, 2011

Project budget for mechanical, electrical, plumbing, fire protection engineering only: $3 million

Engineering challenges

Challenges included identifying and intelligently integrating the MEP/FP sustainable systems so that the building could meet the requirements of a zero net energy building. U.S. Green Building Council LEED Silver as well as a zero net energy rating for the building are the primary project goals. This facility is noted as being the Commonwealth’s first zero net energy (ZNE) building, meaning that the building will utilize zero net energy consumption and emit zero carbon emissions annually.

Solutions

Systems integrated included: high-efficiency mechanical systems, 80 geothermal wells for heating and cooling, a roof with mounted photovoltaic panels, and a green roof.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me