Non-isolated point-of-load power modules

The UDXS0606 and UVXS0606 non-isolated point-of-load (POL) power modules are dual 6-amp POL modules designed to provide ultra-tight voltage regulation and employ a PMBus interface for digital configuration, communication, and control.

12/05/2014


The UDXS0606 and UVXS0606 non-isolated point-of-load (POL) power modules are dual 6-amp POL modules designed to provide ultra-tight voltage regulation and employ a PMBus interface for digital configuration, communication and control. Courtesy: GE Critical

GE's Critical Power's UDXS0606 and UVXS0606 non-isolated point-of-load (POL) power modules are dual 6-amp POL modules designed to provide ultra-tight voltage regulation, digital trim for power reduction, digital sequencing, over-temperature protection, output over-current protection (non-latching), and over-voltage protection. The UDXS0606 (digital) and UVXS0606 (analog) power modules also employ a PMBus interface for digital configuration, communication and control. These features provide power density in a single, flexible module. A single PMBus address can be used for two rails. The DualDLynx occupies up to 25% less board area over separate modules.

GE Critical Power

www.gecriticalpower.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
January/February 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me