New Products

Steam turbine installs in a high-pressure steam distribution system in parallel with existing pressure-reducing valves to drive an electric generator. Components include a high-efficiency turbine, epicyclic speed-reduction gear and 460-volt induction generator. The system can produce 275 kW of electrical power.

08/01/2006


Steam turbine installs in a high-pressure steam distribution system in parallel with existing pressure-reducing valves to drive an electric generator. Components include a high-efficiency turbine, epicyclic speed-reduction gear and 460-volt induction generator. The system can produce 275 kW of electrical power.(Microsteam by Carrier) www.carrier.com #6

Condensing boilers are available in six different sizes from 300,000 to 1 million BTUs per hr. capacity.pm to satisfy environmental requirements. (Modulex by AERCO) www.aerco.com #7

Pump station offers modular distribution for hydronic heating. Besides the circulator, the station’s components are 100% brass and come complete to supply high temp, radiant floor and DHW. There are three different low-temp modules for heating zones with motorized or thermostatic mixing valve and one module for high temp zones or boiler primary loop. (PAW by Solarnetix) www.solarnetix.com #8

UPS management software monitors and manages UPS systems for workstations, servers, networks, data centers and facilities. One application includes automatic model detection, sequential shutdown, stealth mode operation and a cost calculator. The other is enterprise-wide UPS monitoring software that allows administrators to monitor multiple UPS and other power components. (LanSafe and PowerVision by Eaton) www.powerware.com #9

Ballast checker tool identifies ballast type to confirm ballast status and pinpoint lighting upgrade opportunities. When pointed at a fixture, the device turns green if the light source is powered by a high-frequency electronic ballast, orange if it’s powered by a magnetic ballast. It can also be used to verify that a fixture has been installed with an electronic ballast post-installation. (Ballast Checker by Advance) www.ballastchecker.com #10

Fire-rated poke-throughs install in a 4-in. core hole. The FRPTs include a “step-down” feature, enabling wiring, installation and removal, if necessary, from the floor above. Also included on the model is a subplate that incorporates two rectangular openings with up to six-port multi-service or 12-port all-communication service for power and/or data. (SystemOne by Hubbell) www.hubbell-wiring.com #11





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me