New Products for Fire Protection 12/1/04

12/02/2004



Fire alarm control panel product lines are being expanded. The analog addressable control panel is said to be ideal for commercial, institutional, and industrial life safety applications. The panels can accommodate up to sixteen 600 series expansion modules and can support up to 128 conventional input circuits or more than 2,000 addressable points using the XP95 protocol. With the SmartScan protocol, up to 3,168 addressable points can be accommodated.
For more information on IdentiFlex 654/658 and IF 632 from Gamewell, click here .


Flexible sprinkler connection products will now be marketed jointly with CPVC pipes and fittings. Until now, chemical compatibility issues have presented challenges for those looking to take advantage of labor savings and other installation benefits of using CPVC pipe and a flexible sprinkler connection using a stainless steel hose assembly. This combined system is intended to simplify installation, while saving on labor, inspection, maintenance and future relocation of automatic sprinklers.
For more information on Flexhead and Blazemaster, click here and here .

Variable speed electric fire pump controller is said to be a first for the industry. The controller adjusts pump speed to maintain a truly constant output pressure from shut-off to rated flow. It adjusts for large suction pressure variations without wasting water and is UL listed for fire protection in accordance with NFPA 20-2003. Because the output pressure of a centrifugal pump varies with the square of the speed, pressure can be controlled accurately by controlling the speed of the pump. For more information, click here .

Intelligent fire-alarm control panel is a single loop system designed specifically for use in smaller applications. The model can be easily expanded as a company’s safety requirements grow—eliminating the need to replace the entire system when a larger system is needed. The unit turns every networked device into a peer capable of generating accurate and highly detailed information. When a sensor detects a fire, it not only alerts the alarm panel, it can also perform critical process management such as shutdowns, HVAC, elevators, dampers, doors, voice evacuation systems, and security/CCTV/building management awareness. For more about CyberCat 254 from Fike, click here .

Mist control center is a completely pre-piped and pre-wired pump skid assembly that includes the pump, controller, control valves, deluge valve, control panel and system strainer, yet is compact enough to fit through a standard doorway. Designed as an alternative to gaseous, foam and heavy density sprinkler systems, the system uses specially designed mist application nozzles that produce reduced droplet sizes in the discharge pattern. In a fire condition, the fine mist is transformed to steam, expanding each water droplet by over 1,600 times its initial volume and displacing oxygen. For more information about AquaMist from Tyco, click here .





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me