New PLC series improves price/performance ratio

AutomationDirect launches new Do-more PLC and counter module delivering high-end features and performance for an economical price.

09/28/2012


AutomationDirect launches new Do-more PLC and counter module delivering high-end features and performance for an economical price.AutomationDirect has released the latest addition to its PLC offerings, the Do-more H2 Series PLC, using the proven DirectLogic DL205 hardware as a platform. This new model supports all base units, discrete and analog I/O modules available for the DL205 PLC. However, it has a much more flexible and advanced design that makes integrating I/O and organizing a program much easier. The H2 CPUs offer four-times more program memory, nine-times more data memory, and operate at speeds up to 20-times faster than current DL205 CPUs. “Higher processor speeds not only decrease program execution time, but also allow the CPUs to support Ethernet connectivity and custom communication protocols as built-in functions,” says Sammy Natsui, AutomationDirect’s PLC product manager.

A Do-more CPU installed in a DL205 9-slot base supports up to 256 I/O points. The I/O configuration window performs full auto-discovery of all I/O modules in the local base, simplifying system configuration. For larger applications, one or more Remote I/O Master modules installed in the local base can each connect to up to 16 remote I/O subsystems, which can provide hundreds of additional I/O points.

H2 series CPUs reduce system cost and space by including embedded communications ports. Device abstraction makes it easy to connect external devices by allowing the user to assign logical names and then refer to those names throughout the program code for ease and clarity.

Programmed using Do-more Designer software that can be download free of charge, the Do-more PLC provides an advanced instruction set to reduce programming time, superior memory mapping to improve data management, and data structures to simplify initial programming and long-term software maintenance.

The Do-more PLC enables developers to write program code before selecting the specific target hardware. Nicknames can be assigned to inputs and outputs, and then later tied to the physical configuration. Within data memory, the developer can allocate partition size by variable types for maximum flexibility.

Natsui points out further advantages of the new software, saying, “With a wide array of high-level program blocks in Do-more, developers can use two or three instructions to program functionality that used to require many lines of hard-to-understand ladder logic.” This simplifies and speeds development, and also promotes standardization. For example, the spreadsheet style Math instruction allows mixing of data types, and accepts formulas and variables. The Math instruction also allows nesting with parentheses to eight levels, and supports trig and statistical functions.

Do-more Designer’s built-in simulator creates a virtual PLC so logic can be tested without a PLC present. The tool simulates discrete and analog I/O, with access to timers, counters, and control bits, as well as PID function.

The accompanying next-generation H2-CTRIO2 high-speed counter module has four independently configurable timer/counter channels (up to 250 kHz) and two pulse output generators (up to 250 kHz). All configuration and profile setup functions are built into the Do-more Designer software to integrate the module with the application logic.

Two available starter kits provide a prewired, three-slot base with choice of Do-more CPU, an eight-point input simulator module, and an eight-point relay output module. Also included are a copy of the Do-more Designer software on CD, a hard copy of the user manual, a USB programming cable, and a coupon for free online training.

www.automationdirect.com

Edited by Peter Welander, pwelander@cfemedia.com

AutomationDirect is a CSIA member as of 2/26/2015



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me