New lead pipe requirements

California lead content requirements for plumbing products effective Jan. 1, 2010.

04/29/2009


New lead content requirements for plumbing products have been added to California's Health & Safety Code (Section 116875; commonly known as AB1953), which goes into effect Jan. 1, 2010. After this date, any pipe, fitting, or fixture intended to convey or dispense water for human consumption through drinking or cooking must meet a weighted average lead content of <0.25%. The requirement of this law was incorporated as an annex into the American National Standard for health effects of drinking water system components: NSF/ANSI Standard 61 .

Recently, however, there have been misleading statements from some industry sources indicating NSF 61, Annex G does not provide for compliance with the requirements of AB1953.

East Bay Municipal Utility District (EBMUD), which provides water to over 1.3 million residents in the eastern San Francisco Bay Area, was one of the original sponsors of AB1953. Representatives from EBMUD worked with other utilities, regulators, plumbing industry and product manufacturing representatives to develop NSF 61, Annex G.
The NSF 61 committee is currently conducting a series of round robin testing with manufacturers, product certification organizations and the California Department of Toxic Substances to validate a referee analysis method for alloy lead content when testing of materials is required. When completed, the method will be incorporated into the standard.

The annex was developed to establish an American National Standard to determine product compliance with the <0.25% maximum weighted average lead content requirement of the California Health & Safety Code, as well as a standard for other states to reference if they are developing similar regulations. A similar law has been enacted in Vermont and is scheduled to take effect Jan. 1, 2010.

Although the California law does not go into effect for several months, NSF is presently certifying products to NSF 61, Annex G. Certified products will bear the above marks signifying compliance with the standard and the new California requirement.

Over 1,650 products have been certified by NSF to meet Annex G requirements. To view NSF/ANSI Standard 61 Annex G certified drinking water system components, visit NSF's Standard 61 Certified Listings . To view NSF/ANSI Standard 14 Annex G certified plumbing products, visit NSF's Standard 14 Certified Listings . NSF will also be testing these products on an ongoing basis to verify that they continue to comply with the mandated lead content restrictions.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me