Multiple hop radios have I/O connections

Banner Engineering's Surecross MultiHop radios are designed for remote applications and can connect to control systems to communicate with input/output devices.

08/30/2011


Banner Engineering Corp. introduces new SureCross MultiHop radios with I/O to its line of industrial wireless products. SureCross MultiHop radios connect to existing plant-wide control systems to communicate with input and output devices. The MultiHop radios are a designed for remote applications such as lift station control, large-scale irrigation automation, detention pond management and other areas where line of sight is not possible due to difficult terrain.

"MultiHop Radios with I/O are designed to easily extend the range of an existing wired network and to expand the reach of process control without the need for lengthy cable runs," said Chris Dales, wireless sales manager at Banner Engineering. "It is also important to note that our MultiHop radios are not limited to areas where only wired power is available. Even with alternative power sources, the radios still maintain all the wireless communication reliability inherent to the SureCross family."

Banner's SureCross MultiHop wireless sensor networks typically consist of one master radio, but may include many repeater and slave radios. The operational modes are selected by the customer via integrated DIP switches, simplifying the specification process. MultiHop radios automatically form self-healing, auto-routing radio networks with multiple hops to extend the range of a Modbus or other serial communication network. In the event a communication pathway becomes unavailable, the radios will find a route back to the network master without operator intervention. Additional integrated network addressing reduces interference from collocated networks, and the built-in site survey capability enables rapid assessment of a location’s transmission properties.

SureCross MultiHop radios transmit at 1 watt with license-free operation in the Industrial Scientific and Medical (ISM) band—no monthly data plan or annual fees are required. With a high-gain antenna, a range of over 6 miles per hop can be achieved. All I/O communication is performed on a Modbus platform and can be easily integrated with existing PLCs, HMIs or other plant-wide systems. MultiHop radios are available in the 2.4 GHz bandwidth to meet worldwide radio compliance restrictions.

www.bannerengineering.com 

Banner Engineering Corp.

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

Wireless articles and tutorials are available at www.controleng.com/wireless.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me