Multifunction protective relaying system

Distance protection is now available in BE1-11f and BE1-11t versions for feeder and transformer protection applications.

10/06/2016


Distance protection is now available in BE1-11f and BE1-11t versions for feeder and transformer protection applications. Basler Electric's BE1-11 multi-function protective relaying system. The BE1-11f includes distance, Volts/Hz and directional power protection and the BE1-11t includes distance, sync-check, and re-closing functions. The distance elements offer protection that's easy to coordinate when compared with overcurrent elements in the same zone of protection. The Volts/Hz element provides anti-islanding protection in feeder and intertie applications with downstream distributed generation. The sync-check element prevents closing of a breaker when power sources on each side of the breaker are not in sync. The directional power elements detect under/over directional power to control backup/local power generation when tying to the grid may not be desired or permitted. The re-closing element provides automatic re-closing of breakers with multiple timed re-closes. 

Basler Electric

www.basler.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me