Multi-touch, high-speed, high noise immunity, low-voltage resistive touchscreen controllers

Rohm Semiconductor new BU21023/BU21024 series of high-speed, high noise immunity, low-voltage resistive touchscreen controllers are the industry’s first to enable multi-touch (two-point) operation and intuitive gesture control, including pinching, spreading and rotating – previously possible only with more expensive capacitive touch systems, the company said. The design can save power, Rohm told Control Engineering.

06/08/2011


Rohm Semiconductor BU21023/BU21024 series of high-speed, high noise immunity, low-voltage resistive touchscreen controllersRohm Semiconductor BU21023 / BU21024 series of high-speed, high noise immunity, low-voltage resistive touchscreen controllers are now available. These new controllers are the industry’s first to enable multi-touch (two-point) operation and intuitive gesture control, including pinching, spreading and rotating – previously possible only with more expensive capacitive touch systems, the company said. The increasing functionality and sophistication of electronic devices drives the demand for touchscreens which are preferred for their ease of use and versatility. In addition they enable direct interaction without the need for input devices. Resistive touchscreens account for over 75% of the touchscreen market, due in large part to their lower cost and higher precision when compared to capacitive technologies. Another advantage is that they allow operation with fingernails or even while wearing gloves, unlike capacitive touchscreens that require a conductor or dielectric.

At Sensors Expo in Rosemont, IL, on June 7, Ruben Balbuena, Rohm senior product marketing manager, told Control Engineering that 8-bit internal preprocessing can perform many functions without waking the main processor for the device, saving power in mobile applications.

 

Those close to the development noted:

  • Resistive touch screens are used on lots of industrial HMI applications.
  • Capacitive devices don't work when gloves are worn or hands are wet or screen is dirty. Until now resistive touchscreen were limited to single touch operations, so common touchscreen gestures like pinch, spread, rotate, scroll were not possible.
  • Industrial systems could see a dramatic increase in functionality without replacing the touchscreen by designing in this new controller IC. 

Nick Ikuta, Rohm senior technical marketing manager, said, “Touchscreen panels are used in a wide variety of applications, including cellular telephones and car navigation systems. The functionality of electronic devices is increasing day by day and operation by touch panel is increasingly shifting toward pinch, spread and other intuitive finger gestures. Until now, in order to actualize functions like these, electrostatic capacitance type touchscreens were the only choice. With the new BU21023/BU21024 series, conventional 4-wire resistive touchscreen designs can be easily expanded to include dual-touch.”

The BU21023/BU21024 series ICs integrate a dedicated analog circuit and CPU for precise two-point coordinate and gesture detection. A calibration function is also built-in that minimizes the effects of panel variations during production as well as fluctuations in touchscreen device characteristics caused by temperature variations or time-based degradation.

- Edited by Mark T. Hoske, Control Engineering, CFE Media, www.controleng.com

Also see www.controleng.com/HMI.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me