Motorola Mobility

Office; Motorola Mobility; Alfa Tech

08/15/2013


This photo shows the interior of building. Courtesy: Alfa TechEngineering firm: Alfa Tech
2013 MEP Giants rank:
63
Project:
Motorola Mobility
Address:
Sunnyvale, Calif., United States
Building type:
Office
Project type:
Other
Engineering services:
Electrical/Power, HVAC
Project timeline:
March 2011 to March 2012
Engineering services budget:
$10.59 million
MEP budget:
$11.72 million

Challenges

The engineering challenges for this multiple-floor (1st, 6th, 7th, and 8th floors; 35,000 sq ft each floor) tenant improvement on a cold shell high-rise building project included the fast track schedule, cost, life safety smoke control redesign due to new 2-hour separation walls required by the city of Sunnyvale, and food service makeup air.

Solutions

For scheduling and cost, the solution was to proceed with an integrated design approach which forces all parties, including engineers and subcontractors, to work together on a hands-on approach to speed up the shop drawing process, responses to requests for information, and field issues. For smoke control, the solution was to hire an expeditor that had worked with the city before to speed up the approval process. For the food service, instead of bringing makeup air from the exterior envelope (not preferred in a high-profile, high-rise building) and conditioning it, the engineer and CMI (the HVAC subcontractor) worked together on a design-assist basis and provided the innovative design, which used the building return air for the kitchen hood makeup air, saving energy and reducing cost.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me