Motor efficiency: NEMA expands energy saving program to 50 Hz

03/27/2007


Rosslyn, VA —Motors globally will be more efficient thanks to a new energy-efficiency standard from NEMA , the National Electrical Manufacturers Association, for the 50 Hz motor. The 50 Hz standard thus joins the 60 Hz motor as part of the NEMA Premium motor program , and will help North American machine builders, end-users, and system integrators that work globally.

The NEMA Premium Motors 50 Hz Standard, expected during early spring 2007, will allow the manufacturers that participate in the NEMA Premium Motors Program to manufacture and market NEMA Premium motors in 60 Hz and 50 Hz configurations worldwide. It will also allow manufacturers of 50 Hz integral motors to license the NEMA Premium brand, promoting energy-efficiency brand.

NEMA Premium Motors are recognized as the leading energy-efficient integral motors in North America. Other standards organizations have widely adopted or mirrored the NEMA MG 1 standard (from NEMA's Motor and Generator Section) for 60 Hz motors. The 50 Hz tables added to MG 1 are also expected to be widely accepted, NEMA says.

NEMA launched its Premium Efficient Electric Motor program in 2001. At the outset of the program, it was estimated that in its first 10 years, the program would save enough electricity to serve as the functional equivalent to equal keeping 16 million cars off the road. The program has exceeded expectations through marketing efforts by the NEMA Motor and Generator Section, and cooperative efforts with Motor Decisions Matter (MDM), a program run by the Consortium for Energy Efficiency (CEE), the American Council for an Energy Efficient Economy (ACEEE), and others. Many electric utilities recognize NEMA Premium and offer rebates for specifying and installing NEMA Premium motors. The members of the Motor and Generator Section represent more than 80% of U.S. production and sales of electric motors.

NEMA Premium efficient motors exceed the minimum energy-efficiency standards required by the Energy Policy Act of 1992. The minimum standards imposed on certain 1-200 hp general-purpose integral motors are based on NEMA standards.

The Energy Efficiency in Motor Driven Systems (EEMODS) '07 conference in Beijing, China, June 10-13, will include a paper highlighting the NEMA Premium program. The EEMODS conference comes at a time when the world in general—and the Chinese in particular—continues to search for energy-efficient products. The NEMA office in Beijing will extend invitations to attend the conference to Chinese officials who show vital interest in energy-efficient motor design and systems. NEMA members are also encouraged to attend. Register for the conference at www.eemods.org .

—Edited by Mark T. Hoske , editor in chief,
Control Engineering Weekly News (Register here and scroll down to select your choice of eNewsletters free.)





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me