Motor design software suite

CD-Adapco Speed 2012 software design suite covers brushless permanent magnet (PM) motors, induction motors, DC brush motors, DC and AC wound field motors, and switched reluctance motors.

10/03/2012


CD-Adapco SPEED 2012 software design suite shows the cross section editor (PC-BDC). Courtesy: CD-AdapcoThe CD-Adapco Speed 2012 software design suite release consisting of the following five main machine programs:

1. PC-BDC Brushless PM Motors (issue 9.1)

2. PC-IMD Induction Motors (issue 4.2)

3. PC-DCM DC Brush Motors (issue 3.9)

4. PC-WFC DC and AC Wound Field Motors (issue 2.7)

5. PC-SRD Switched Reluctance Motors (issue 8.8)

CD-Adapco SPEED 2012 software design suite shows flux density distribution (PC-FEA). Courtesy: CD-AdapcoThese are available with a floating license system using FlexLM and a link that was established to Star-CCM+ (the CFD program of CD-adapco) to exchange the data needed from Speed (mainly geometry and losses) to Star-CCM+ to setup the CFD 3D model and run an advanced thermal calculation of the electrical machine (see three images).

Each Speed program is intended for designing and calculating a wide range of electro-magnetic machine performances. The design processes used in all Speed programs are fast and efficient. Templates are used to establish the machine’s dimensions, to assist in laying out the winding, to select the desired materials, and to compute the machine’s performance at one operating point, or over a whole speed/torque range. A strong link to Speed’s own finite element analysis (FEA) program PC-FEA gives accuracy, a high confidence level and offers the analysis of fine details or even solve difficult problems, the company said.

CD-Adapco SPEED 2012 software design suite shows temperature distribution (STAR-CCM+). Courtesy: CD-AdapcoAlso, scripting facilities (via ActiveX) ease and widen the use of the Speed software.

www.cd-adapco.com

- Edited by Mark T. Hoske, content manager, CFE Media, Control Engineering, and Plant Engineering, mhoske@cfemedia.com.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me