Motor control kit includes 32-bit microcontroller, driver

The DRV8312 motor control kit from Texas Instruments features a 32-bit Stellaris microcontroller and motor driver to spin three-phase brushless DC motors in minutes.

01/04/2012


The DRV8312 motor control kit features a 32-bit Stellaris microcontroller and motor driver to spin three-phase brushless DC motors in minutes. Courtesy: Texas InstrumentsTexas Instruments Incorporated (NYSE: TXN) announced a motor control kit for spinning three-phase brushless motors with a Stellaris Cortex-M3 microcontroller (MCU). The DK-LM3S-DRV8312 motor control kit features a 32-bit Stellaris LM3S818 microcontroller and DRV8312 motor driver to spin sub-50 V, 6.5 A three-phase brushless dc (BLDC) motors in minutes. This solution is for high-volume motor control applications, including low-voltage fans, blowers, pumps, tools and compressors.

The Stellaris LM3S818 controlCard module included in the kit has the required firmware pre-programmed in flash memory to run TI’s InstaSPIN-BLDC solution out-of-the-box, along with other customer-developed applications, when plugged into the DRV8312 motor driver base board. The InstaSPIN-BLDC solution is an innovative and free back-electromagnetic field (EMF) technique that spins any motor in seconds without knowledge of any motor parameters. Unlike traditional back-EMF zero crossing techniques, InstaSPIN-BLDC extends sensorless operation down to lower speeds and exhibits high immunity to miscommutation caused by rapid speed changes. Reliable motor start-up has been demonstrated over a wide range of conditions, including full torque.

Features and benefits of the Stellaris motor control kit include:

  • The controlCard module with Stellaris LM3S818 MCU features 50 MHz performance, 64 KB flash, 8 KB SRAM and 6 PWM generators, allowing developers to create complex motion control designs with a tiny footprint.
  • DRV8312 motor driver provides output up to 6.5 A, without the need for a costly external heat sink. It is a fully protected motor driver with cycle-by-cycle over-current, over-temperature, cross-conduction and under-voltage protection, reducing design complexity and board space.
  • Kit includes a 24 V three-phase BLDC motor operating at up to 3.5 A continuously.
  • Supporting software includes StellarisWare software with TI’s IQmath Library for easy fixed to floating point conversion and InstaSpin-BLDC software for quick and reliable motor start-up on any motor.
  • Accelerated system design with intuitive graphical user interface (GUI).

Texas Instruments Incorporated

www.ti.com

- Edited by Chris Vavra, Control Engineering, www.controleng.com

See the more motor and drives technologies at controleng.com/motors



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me