Motion control system software configures, analyzes, tunes

GalilSuite is designed to configure, analyze, and tune Galil motion control systems. The software comes with terminal, editor, tuner, scope and watch tools to streamline operations for motion controls.

02/14/2012


GalilSuite is designed to configure, analyze, and tune Galil motion control systems. The software comes with terminal, editor, tuner, scope and watch tools to streamline operations for motion controls. Courtesy: Galil Motion ControlGalil Motion Control's GalilSuite Software Package, is their software for configuring, analyzing and tuning Galil motion control systems. GalilSuite is a replacement for Galil's prior generation GalilTools software and offers more advanced features and flexibility. It has enhanced servo tuning capabilities and provides multiple tuning methods making it easy to automatically tune many types of control systems. The new software also allows multiple connections to be made from GalilSuite to multiple controllers.

The GalilSuite software package provides five tools for working with Galil controllers:

  • Terminal - for sending and receiving controller commands
  • Editor - for writing, saving and executing application programs
  • Tuner - for selecting controller PID parameters for optimal servo system response
  • Scope - for plotting controller data such as motor position and velocity
  • Watch - for displaying controller and I/O status

In GalilSuite each of these tools are independent and can be launched and run individually. This feature makes it easy for the design engineer to create a flexible development environment for testing control systems.

The Terminal Tool allows Galil commands to be easily sent to and from Galil controllers and provides a Command Helper with Syntax Checker. The Editor Tool allows controller programs to be opened, edited and saved. The enhanced editor is full featured and provides cut, paste, copy, insert and find/replace functions in addition to a syntax helper which includes label detection and syntax help.

The Tuner Tool has many enhancements and provides numerous methods for servo tuning including Crossover, General, Curve Follower and Manual which allows the user to select the optimum method for tuning his system. The user can also select the final test profile as a sine wave, step response, profiled move or custom user code. For each method, the tuner scope captures and displays the controller command position, encoder position, position error and torque in response to the specified test profile.

The Scope Tool is easier to use and has more features than the prior generation. One enhanced feature is that a virtually unlimited number of traces can be displayed such as position, position error, torque, I/O status and amplifier status. The scale for each trace can be adjusted separately along with its position on the scope display. The scope also provides a drag and drop feature allowing easy selection of a parameter from the controller data record by dragging it into the scope display.

The Watch Tool provides an easy-to-read display of various controller data such as controller and amplifier status, I/O and motion parameters. Digital input and output status is shown with virtual LEDs and data such as axis position is shown in numeric format in a table. The update rate of the data capture is selectable.

Galil Motion Control

www.galilmc.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

For more on motors, drives, and motion technologies, see

controleng.com/motors



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me