Molded case circuit breaker

The PowerPact B-frame circuit breaker is designed to offer robust power protection in a compact size and 'efficiency that clicks' to the work day.

12/29/2016


The PowerPact B-frame circuit breaker is designed to offer robust power protection in a compact size and efficiency that clicks to the work day. Courtesy: Schneider ElectricThe PowerPact B-frame circuit breaker is designed to offer robust power protection in a compact size and "efficiency that clicks" to the work day. The 125 A B-frame circuit breaker is the smallest Square D molded case circuit breaker offered in the PowerPact range. It utilizes economical, thermal magnetic sensing elements and is designed to be flexible and offer integrated DIN rail and back-pan mounting capabilities without extra adapter brackets. A wide variety of external mechanical operators for control panel applications complement field-installable electrical accessories. PowerPact B circuit breakers also feature EverLink creep-compensating lug technology. This spring-based power terminal system ensures a lasting connection by mitigating the loosening effects of heat cycling or vibration. The lugs are UL listed for use directly with stranded and fine-stranded wire up to Class K. EverLink lugs are even offered with optional built-in control wire terminals.

Schneider Electric

www.schneider-electric.us 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me