Modular cooling system

The HP Modular Cooling System (HP MCS) 100 and 200 are close-coupled cooling systems that can effectively cool fully populated high-density racks, which save floor space and cooling resources.

05/06/2014


The HP Modular Cooling System (HP MCS) 100 and 200 are close-coupled cooling systems that can effectively cool fully populated high-density racks, which save floor space and cooling resources. Courtesy: Hewlett-PackardThe HP Modular Cooling System (HP MCS) 100 and 200 are close-coupled cooling systems that can handle rack power and cooling requirements from 5,000 to 50,000 W without adding to the current heat load on the existing conventional data center cooling system. The HP MCS 100 and 200 can effectively cool fully populated high-density racks, which save floor space and cooling resources. Each server receives an adequate air supply, regardless of its position within the rack or the rack's density. As the servers expel warm exhaust air out the rear of the rack, the fan modules redirect the warm air into the heat exchanger module. The air is recooled and then recirculated to the front of the rack. The HP MCS 100 offers 5,000 to 35,000 W capacity, and the HP MCS 200 offers 10,000 to 50,000 W. Each model is capable of cooling one or two racks.

Hewlett-Packard (HP)

www.hp.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me