Modbus gateways with integrated Ethernet cascading

Advantech’s modbus gateways, the EKI-1221D and EKI-1222D, feature built-in Ethernet switches and provide transparent connectivity between Modbus serial devices and Ethernet-based Modbus/TCP equipment.

02/04/2011


Advantech Industrial Automation Group introduces two new modbus gateways with built-in Ethernet switches, the EKI-1221D and EKI-1222D. They both provide transparent connectivity between Modbus (ASCII, RTU) serial devices and Ethernet based Modbus/TCP equipment. They are able to fulfill flexible installation and web browser configuration requirements for remote monitoring applications.

They have built-in Ethernet switches for cascading/daisy-chain connectivity that offers flexible cabling. Cascading connections support Ethernet auto-bypass to prevent accidental power failure in the event one of the Modbus Gateway’s unexpectedly shuts down. They come with Windows utilities and web-based configuration, providing easier ways to set up. One port can be used to connect to the network, while the other can be used to connect to an Ethernet device or another EKI-1221D/1222D. For instance, one Ethernet port connects to an HMI, while another Ethernet port can connect to a PAC, allowing these devices to easily communicate. This provides a simple and cost-effective way to add remote management and data accessibility to thousand of devices that can’t connect to a network.

They provide 921k baud speeds and are designed to fulfill any master/slave relationship. Moreover, they support 16 TCP masters, 16 TCP slaves, and each serial port supports up to 31 RTU/ASCII slave devices.

They have built-in dual power inputs (12~48 Vdc) with one power fail relay output to detect power operation status and ensure reliable operation. They are built with thin DIN-rail mount form factors, IP30 metal housings, and Class I Division 2 certification for hazardous environment requirement.

www.advantech.com/ea

Advantech Corporation, Industrial Automation Group

- Edited by Amanda McLeman, Control Engineering, www.controleng.com

Advantech Corporation is a CSIA member as of 2/26/2015



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me